Inductively Coupled Plasma Specifications
Inductively Coupled Plasma
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
R
S
T
U
V
W
X
Y
Z
  • Hafnium 1000 ppm PrimAg

    element reference solution
    E3HF#
    100ml E3HF#S
    500ml E3HF#P
    Wng H:290
    Hf AW 178.49
    1000 ppm as Hf
    Solute: HfOCl2
    Matrix: HCl 0.5M
    Application: AA, ICP and IC calibration
    SI-traceable, ISO 17034 accredited
    100ml E3HF#S
    500ml E3HF#P
    Wng H:290
  • Hafnium 10,000 ppm PrimAg

    element reference concentrate
    N7HF#
    100ml N7HF#S
    500ml N7HF#P
    Wng H:290
    Hf AW 178.49
    10,000 ppm as Hf
    Solute: HfOCl2
    Matrix: HCl 1M
    Application: ICP calibration
    SI-traceable, ISO 17034 accredited
    100ml N7HF#S
    500ml N7HF#P
    Wng H:290
  • Holmium 1000 ppm PrimAg

    element reference solution
    E3HO#
    100ml E3HO#S
    500ml E3HO#P
    Dgr H:315-318
    P:280e-302+352-305+351+338-310
    Ho AW 164.93
    1000 ppm as Ho
    Solute: Ho2O3
    Matrix: HNO3 0.5M
    Application: AA, ICP and IC calibration
    SI-traceable, ISO 17034 accredited
    100ml E3HO#S
    500ml E3HO#P
    Dgr H:315-318
    P:280e-302+352-305+351+338-310
  • Hydrobromic Acid UpA

    SS82
    500ml SS82P
    Dgr H:314-335
    P:280c-301+330+331-304+340-305+351+338-309+310
    HBr MW 80.91 d 1.48 CAS [10035-10-6]
    Assay 44-49%
    Trace elemental impurities: parts per trillion level
    Batch values reported on accompanying Certificate of Analysis
    Application: Ultra trace inorganic analysis
    Typical values, elemental impurities at time of manufacture (ppt):
    Ag<2Cu<5Lu<0.01Re<5Tl<0.1
    Al<50Dy<0.01Mg<5Rh<1Tm<0.01
    Au<1Er<0.01Mn<2Ru<10U<0.01
    B<1000Eu<0.01Mo<10Sb<50V<1
    Ba<1Fe<50Na<30Sc<1W<10
    Be<5Ga<10Nb<1Sm<0.01Y<1
    Bi<0.1Gd<0.01Nd<0.05Sn<20Yb<0.01
    Ca<50Hf<0.05Ni<10Sr<1Zn<5
    Cd<1Ho<0.01Pb<1Ta<20Zr<1
    Ce<0.05In<1Pd<10Tb<0.01
    Co<1K<20Pr<0.05Te<10
    Cr<10La<0.05Pt<1Th<0.05
    Cs<0.05Li<1Rb<1Ti<10
    500ml SS82P
    Dgr H:314-335
    P:280c-301+330+331-304+340-305+351+338-309+310
  • Hydrochloric Acid SpA

    H396
    500ml H396P
    1LT H396M
    2½LT H396L
    Dgr H:290-314-335
    P:280c-301+330+331-305+351+338-309+310
    HCl MW 36.46 d 1.18 CAS [7647-01-0]
    Assay 34-37%
    Colour <10 Hazen (APHA)
    Ba, Be, Bi, Cd, Ce, Co, Cs, Dy, Er, Eu, Ga, Gd, Hf, Ho, In, La, Li, Lu, Mn, Mo, Nb, Nd, Pb, Pr, Rb, Re, Rh, Ru, Sc, Sm, Sr, Tb, Te, Th, Tl, Tm, U, W, Y, Yb, Zr <0.1 ppb each
    As, Au, Cr, Cu, Hg, Mg, Ni, Sb, Sn, Ti, V <0.5 ppb each
    Ag, Al, B, Ca, Fe, K, Na, Se, Zn <1 ppb each
    Total P <0.01 ppm
    Total S <0.3 ppm
    Free Cl2 <0.5 ppm
    Br <10 ppm
    Application: Environment Analysis (eg, using AAS, ICP-OES, ICP-MS), Trace Metal Analysis, Ion Chromatography, Voltammetry
    Elemental impurities specified at time of manufacture.
    Typical values, elemental impurities at time of manufacture (ppb):
    Ag<0.1Cs<0.1La<0.1Pt<0.5Te<0.1
    Al<0.5Cu<0.1Li<0.1Rb<0.1Th<0.1
    As<0.1Dy<0.1Lu<0.1Re<0.1Ti<0.1
    Au<0.1Er<0.1Mg<0.5Rh<0.1Tl<0.1
    B<0.5Eu<0.1Mn<0.1Ru<0.1Tm<0.1
    Ba<0.1Fe<0.5Mo<0.1Sb<0.1U<0.1
    Be<0.1Ga<0.1Na<0.5Sc<0.1V<0.1
    Bi<0.1Gd<0.1Nb<0.1Se<0.1W<0.1
    Ca<0.5Hf<0.1Nd<0.1Sm<0.1Y<0.1
    Cd<0.1Hg<0.2Ni<0.1Sn<0.1Yb<0.1
    Ce<0.1Ho<0.1Pb<0.1Sr<0.1Zn<0.5
    Co<0.1In<0.1Pd<0.5Ta<0.5Zr<0.1
    Cr<0.1K<0.1Pr<0.1Tb<0.1
    500ml H396P
    1LT H396M
    2½LT H396L
    Dgr H:290-314-335
    P:280c-301+330+331-305+351+338-309+310
  • Hydrochloric Acid UpA

    SS42
    500ml SS42P
    Dgr H:290-314-335
    P:280c-301+330+331-305+351+338-309+310
    HCl MW 36.46 d 1.18 CAS [7647-01-0]
    Assay 32-35%
    Trace elemental impurities: parts per trillion level
    Batch values reported on accompanying Certificate of Analysis
    Application: Ultra trace inorganic analysis
    Typical values, elemental impurities at time of manufacture (ppt):
    Ag<5Cs<0.05La<0.05Pt<1Te<1
    Al<10Cu<3Li<1Rb<1Th<0.05
    As<20Dy<0.01Lu<0.01Re<0.1Ti<10
    Au<10Er<0.01Mg<5Rh<1Tl<0.1
    B<10Eu<0.01Mn<2Ru<10Tm<0.01
    Ba<1Fe<10Mo<5Sb<20U<0.01
    Be<5Ga<1Na<5Sc<1V<1
    Bi<0.05Gd<0.01Nb<1Se<50W<5
    Ca<10Hf<0.05Nd<0.05Sm<0.01Y<0.1
    Cd<0.1Hg<20Ni<10Sn<10Yb<0.01
    Ce<0.05Ho<0.01Pb<1Sr<1Zn<5
    Co<3In<0.1Pd<10Ta<20Zr<1
    Cr<10K<10Pr<0.05Tb<0.01
    500ml SS42P
    Dgr H:290-314-335
    P:280c-301+330+331-305+351+338-309+310
  • Hydrofluoric Acid SpA

    H405
    500ml H405P
    Dgr H:300+310+330-314
    P:280-301+330+331-302+352-304+340-305+351+338-310+ROP010
    HF MW 20.01 d 1.16 CAS [7664-39-3]
    Assay 47-51%
    Colour <10 Hazen (APHA)
    Ba, Be, Bi, Cd, Ce, Co, Cs, Dy, Er, Eu, Ga, Gd, Ge, Hf, Ho, In, La, Li, Lu, Mn, Mo, Nb, Nd, Pb, Pr, Rb, Re, Rh, Ru, Sc, Sm, Sr, Tb, Te, Th, Tl, Tm, U, V, Y, Yb, Zr <0.1 ppb each
    Au, Pd, Pt, Sb <0.2 ppb each
    Ag, As, Cu, Ni, Sn, W <0.5 ppb each
    Al, B, Ca, Cr, Fe, Hg, K, Mg, Na, Se, Ti, Zn <1 ppb each
    Total P <0.05 ppm
    Total S <0.1 ppm
    Cl <4 ppm
    SiF6 <20 ppm
    Application: Environment Analysis (eg, using AAS, ICP-OES, ICP-MS), Trace Metal Analysis, Ion Chromatography, Voltammetry
    Elemental impurities specified at time of manufacture.
    For treatment of HF burns, calcium gluconate gel (ROMIL Code PCG9V) is recommended. In order to provide emergency first aid, it should be kept wherever HF is handled or stored.
    Typical values, elemental impurities at time of manufacture (ppb):
    Ag<0.1Cs<0.1K<0.2Pr<0.1Tb<0.1
    Al<0.5Cu<0.1La<0.1Pt<0.2Te<0.1
    As<0.1Dy<0.1Li<0.1Rb<0.1Th<0.1
    Au<0.1Er<0.1Lu<0.1Re<0.1Ti<0.5
    B<0.5Eu<0.1Mg<0.2Rh<0.1Tl<0.1
    Ba<0.1Fe<0.5Mn<0.1Ru<0.1Tm<0.1
    Be<0.1Ga<0.1Mo<0.1Sb<0.1U<0.1
    Bi<0.1Gd<0.1Na<0.5Sc<0.1V<0.1
    Ca<0.5Ge<0.1Nb<0.1Se<0.1W<0.5
    Cd<0.1Hf<0.1Nd<0.1Sm<0.1Y<0.1
    Ce<0.1Hg<0.05Ni<0.1Sn<0.1Yb<0.1
    Co<0.1Ho<0.1Pb<0.1Sr<0.1Zn<0.1
    Cr<0.1In<0.1Pd<0.2Ta<0.5Zr<0.1
    500ml H405P
    Dgr H:300+310+330-314
    P:280-301+330+331-302+352-304+340-305+351+338-310+ROP010
  • Hydrofluoric Acid UpA

    SS52
    500ml SS52P
    Dgr H:300+310+330-314
    P:280-301+330+331-302+352-304+340-305+351+338-310+ROP010
    HF MW 20.01 d 1.16 CAS [7664-39-3]
    Assay 47-51%
    Trace elemental impurities: parts per trillion level
    Batch values reported on accompanying Certificate of Analysis
    Application: Ultra trace inorganic analysis
    For treatment of HF burns, calcium gluconate gel (ROMIL Code PCG9V) is recommended. In order to provide emergency first aid, it should be kept wherever HF is handled or stored.
    Typical values, elemental impurities at time of manufacture (ppt):
    Ag<1Cs<0.5K<10Pr<0.1Tb<0.1
    Al<10Cu<10La<0.1Pt<10Te<1
    As<10Dy<0.1Li<1Rb<1Th<0.1
    Au<10Er<0.1Lu<0.1Re<0.1Ti<10
    B<10Eu<0.1Mg<5Rh<1Tl<0.1
    Ba<5Fe<10Mn<1Ru<1Tm<0.1
    Be<5Ga<1Mo<5Sb<10U<0.1
    Bi<0.1Gd<0.1Na<10Sc<1V<1
    Ca<10Ge<1Nb<5Se<50W<10
    Cd<0.1Hf<1Nd<0.1Sm<0.1Y<0.5
    Ce<0.1Hg<20Ni<10Sn<10Yb<0.1
    Co<1Ho<0.1Pb<1Sr<1Zn<5
    Cr<10In<0.1Pd<10Ta<20Zr<10
    Typical values, anionic impurities at time of manufacture (ppb):
    Total S <50
    500ml SS52P
    Dgr H:300+310+330-314
    P:280-301+330+331-302+352-304+340-305+351+338-310+ROP010
  • Hydrogen Peroxide SpA

    H416
    500ml H416P
    Dgr H:302-318
    P:280e-305+351+338-313
    H2O2 MW 34.01 d 1.10 CAS [7722-84-1]
    Assay ca. 30%
    Colour <10 Hazen (APHA)
    B, Be, Bi, Ce, Co, Cs, Dy, Er, Eu, Ga, Gd, Hf, Ho, Ir, La, Lu, Mn, Nd, Pd, Pt, Rb, Re, Rh, Ru, Sc, Sm, Sr, Tb, Te, Th, Tl, Tm, U, Y, Yb <0.5 ppb each
    Ba, Cu, Cr, Sb <1 ppb each
    Ag, As, Cd, Ge, In, Li, Mg, Mo, Ni, Pb, Se, Sn, V, Zr <5 ppb each
    Al, Ti, Zn <10 ppb each
    Au, Ca, Fe, Hg, K, Na, Nb, Ta, W <50 ppb each
    Cl, PO4 <0.5 ppm each
    SO4, NO3 <1 ppm each
    Application: Environment Analysis (eg, using AAS, ICP-OES, ICP-MS), Trace Metal Analysis, Ion Chromatography, Voltammetry
    Elemental impurities specified at time of manufacture.
    As a safety measure we fit bottles with a closure featuring a venting valve.
    Typical values, elemental impurities at time of manufacture (ppb):
    Ag2Cs<0.1Ir<0.1Pd<0.1Tb<0.1
    Al<0.1Cu<0.1K15Pt<0.1Te<0.1
    As<0.1Dy<0.1La<0.1Rb<0.1Th<0.1
    Au<0.1Er<0.1Li<0.1Re<0.1Ti4
    B<0.1Eu<0.1Lu<0.1Rh<0.1Tl<0.1
    Ba<0.1Fe<6Mg<0.1Ru<0.1Tm<0.1
    Be<0.1Ga<0.1Mn<0.1Sb<0.1U<0.1
    Bi<0.1Gd<0.1Mo<0.1Sc<0.1V<0.1
    Ca<0.1Ge<0.1Na16Se2W1
    Cd<0.1Hf<0.1Nb0.2Sm<0.1Y<0.1
    Ce<0.1Hg3Nd<0.1Sn<0.1Yb<0.1
    Co<0.1Ho<0.1Ni<0.1Sr<0.1Zn2
    Cr<0.1In<0.1Pb<0.1Ta1Zr2
    500ml H416P
    Dgr H:302-318
    P:280e-305+351+338-313
  • Hydrogen Peroxide UpA

    SS92
    500ml SS92P
    Dgr H:302-318
    P:280e-305+351+338-313
    H2O2 MW 34.01 d 1.10 CAS [7722-84-1]
    Assay 30-32%
    Trace elemental impurities: parts per trillion level
    Batch values reported on accompanying Certificate of Analysis
    Application: Ultra trace inorganic analysis
    Typical values, elemental impurities at time of manufacture (ppt):
    Ag<10Cs<1K<10Pr<0.5Te<1
    Al<10Cu<5La<0.5Rb<5Th<0.5
    As<10Dy<0.5Li<1Re<5Ti<10
    Au<10Er<0.5Lu<0.5Rh<5Tl<1
    B<100Eu<0.5Mg<10Ru<10Tm<0.5
    Ba<5Fe<20Mn<5Sb<1U<0.5
    Be<5Ga<5Mo<5Sc<10V<5
    Bi<10Gd<0.5Na<10Se<50W<10
    Ca<50Ge<10Nb<1Sm<0.5Y<1
    Cd<1Hf<1Nd<0.5Sn<10Yb<0.5
    Ce<1Hg<20Ni<10Sr<1Zn<10
    Co<5Ho<0.5Pb<1Ta<10Zr<5
    Cr<5In<0.5Pd<10Tb<0.5
    500ml SS92P
    Dgr H:302-318
    P:280e-305+351+338-313